Ozone Generator - Puroxi

Benefits of Ozone in Aquaculture

By choosing ozone and UV light, you’re not just getting a powerful pool maintenance solution; you’re also making a sustainable choice. Ozone and UV light are nature’s renewable resources, oxidizing organic and inorganic matter without forming by-products such as chloramines, which are responsible for the chlorine smell.

Quanju are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.

Fine and colloidal solids consist of particles 1-30 microns (mm) and 0.001-1 mm, respectively. The small size of the particles enables the solids to remain in suspension and avoid most mechanical methods of separation. The accumulation of fine and colloidal solids can impair biofilter nitrification efficiencies and stress fish stocks.

Ozone plays a crucial role in aquaculture systems by effectively removing fine and colloidal solids. It achieves this by clumping these particles together (microflocculation) and facilitating their removal through foam fractionation, filtration, and sedimentation.

Dissolved organic compounds (DOCs), also known as refractory organics, can significantly impact our aquaculture systems. They give the water a characteristic tea-coloured stain and are non-biodegradable, accumulating according to feed input, water exchange rate, and solids. High levels of DOCs can stress our fish and reduce the biofilter’s nitrification efficiencies, a concern we must address.

Nitrite can accumulate as production intensifies and organic loadings on the biofilter increase. Bacteria that process ammonia into nitrite (Nitrosomonas spp) operate more efficiently under high organic loadings than bacteria that process nitrite to nitrate (Nitrobacter), and nitrite levels rise accordingly.

It’s crucial to note that high nitrite levels can be extremely toxic to our fish. Data available for silver perch Bidyanus biryanis indicates that nitrite levels as low as 2.8 parts per million (ppm) can reduce the growth of fingerlings by 5%, a significant impact we need to prevent.

The high stocking densities, associated fish stress, and increased nutrient loads found in RAS (recirculating aquaculture systems) create an ideal environment for fish pathogens. Standard quarantine procedures for any fish introduced are an essential step in reducing the risk of disease outbreaks in RAS. Facilities using surface waters, including RAS and flow-through hatchery systems, are also interested in reducing the pathogen load introduced via the source water. The disinfection of effluent waters before introduction to the environment is also crucial to prevent the translocation of exotic diseases.

Ozone can effectively inactivate various bacterial, viral, fungal and protozoan fish pathogens. The effectiveness of ozone treatment depends on ozone concentration, length of ozone exposure (contact time), pathogen loads and levels of organic matter. If high levels of organic matter are present, the demand created by oxidizing the organic matter can make it challenging to maintain enough residual ozone for effective disinfection.

Are you interested in learning more about 20g ozone generator? Contact us today to secure an expert consultation!

The direct ozone measurement in a water sample is generally achieved using colorimetric test kits and spectrophotometry. However, these methods can be too coarse to detect the low residual levels lethal to some fish species and are unsuitable for continuous in-flow monitoring.

A common way of providing some level of constant in-flow monitoring for ozone is using oxidation-reduction potential (ORP) probes. Rather than measure ozone directly, an ORP probe measures the total capacity of various oxidants in millivolts (mV) in a solution to oxidize an electrode. These oxidants, often called ‘total oxidants, ‘include ozone and other reactive species such as chlorine and hydrogen peroxide. Keeping ORP measurements within a specific range, the levels of total oxidants can be controlled, which gives indirect control over ozone. A safe ORP level of freshwater fish culture is generally considered 300 mV.

Many systems automate ozonation by linking ORP measurement and the ozone generator. The generator switches off once the required ORP is reached and cuts back when the ORP drops again. This adaptability of ORP measurement to factors such as pH, temperature, and species culture reassures the system’s effectiveness. However, due to the lack of direct ozone measurement and because ORP probes can take several minutes to register a charge in ORP, any use of ORP to measure and control ozone application is approximate. For this reason, ozone control using ORP measurements is recommended to allow for some error and to set limits conservatively. Other water quality parameters, particularly nitrite, should also be monitored closely with ORP and used to gauge the effect of ozonation.

Ozone is an effective oxidizing agent for water treatment and reducing pathogen loads in RAS. However, using any chemical of this nature is accompanied by considerable risks. RAS viability may be threatened in several ways.

It is recommended that a de-ozonation unit be installed directly after ozone application in an RAS to prevent toxic residual levels. This should be done regardless of the location of the ozone application in the system. A simple do-ozonation unit consists of a contact chamber to increase water retention time, allowing ozone to degrade. Alternatively, an in-line activated carbon filter or biofilter can also function as a de-ozonation unit. Degassing of residual ozone also occurs in packed column aerators and trickle filters. Any residual ozone gas should be vented from the RAS building and destroyed before release. Ozone is extremely toxic, and human exposure constitutes a serious health hazard. Decrease in lung function, aggravation of asthma, throat irritation and cough, chest pain, shortness of breath, and inflammation of lung tissue are typical symptoms of ozone exposure. In prolonged or severe exposure cases, chronic respiratory illnesses such as emphysema, chronic bronchitis, and premature aging of the lungs may occur.

Exposure standards for residual ozone in various Australian and international occupational health and safety administrations range between 0.05 and 0.1 ppm for an 8-hour work period and a maximum single dosage of 0.3 ppm for less than 10 minutes. Workcover Australia has a maximum exposure standard for residual ozone of 0.1 ppm for 8 hours.

Therefore, it is important to repeat the requirements of a leak-free ozone reactor made of suitable ozone-resistant materials. Venting sheds or areas of an RAS where ozone is used is also highly recommended. Humans can detect low residual ozone levels as a sharp, pungent odour, but continued exposure can quickly dull the senses. For this reason, perceived odour should not be used as an indicator of ozone presence.

If you are looking for more details, kindly visit Portable Oxygen Concentrator 5 Litres.

1

0

Comments

0/2000

All Comments (0)

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name (required)

Your Email (required)

Subject

Your Message (required)

0/2000