How to Choose Laboratory Ventilation In HVAC?
Apr. 07, 2025
How to Design Laboratory Ventilation - Greenheck
The COVID-19 pandemic exposed the need for more information in fighting contagious diseases. Research on its causes, controls and cures spiked and continue still as the world attempts to protect against such viruses. Of course, laboratories work on a variety of projects in addition to contagious diseases and all need varying levels of protection to maintain a safe work environment. The need for safe laboratory ventilation always exists, regardless of the type of research conducted. However, questions remain when it comes to specifying these ventilation systems, specifically laboratory exhaust systems. What is the proper level of protection to specify?
The answer is, it depends. A one-size-fits-all approach to laboratory ventilation is not the answer as the level and type of research done in laboratories varies. A high school lab does not have the same requirements as a laboratory doing research on infectious diseases. Fortunately, there is help.
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) have released a publication that will help. Classification of Laboratory Design Levels is a guide that addresses:
• Design and operation of laboratories
• Interactions with laboratory airflow control systems (LACSs) that provide conditioning
• Control of environmental air quality in a laboratory
If you are looking for more details, kindly visit our website.
Figure 1 – represents a simplified diagram of a laboratory and LACS showing critical components. (Image courtesy of The American Society of Heating, Refrigerating and Air-Conditioning Engineers. (ASHRAE))
ASHRAE’s guide covers the entire spectrum of ventilation for laboratories. For simplification, let’s focus on items to consider when designing laboratory exhaust system and the LVDL. These include fan redundancy, protection of fan drive components from the airstream, a bypass air plenum and damper, drive type, fan discharge, and system height.
Number of Exhaust Fans – Fan Redundancy
Quantity of fans in an exhaust system depends on the amount of air being exhausted, LVDL recommendation on equipment redundancy and the results of a risk assessment performed during the design process.
Single fan use in LVDL 0, 1 or 2 laboratories is acceptable and if the laboratory risk assessment is a low. The use of a single fan is often with dedicated exhaust to a single hood or space.
ASHRAE LVDL 3 or 4 recommends equipment redundancy. Redundancy provides a back-up fan in the event of a failure to maintain containment in the laboratory. This recommendation is an important consideration as the hazard level increases along with the hazard potential of the work being performed in the facility.
Multiple fans offer system redundancy and higher system airflow capacities when multiple hoods are manifolded together. In addition, multiple fans provide the control option to stage fan operation, reducing operational costs when risk levels are monitored. Ventilation rates for occupied or unoccupied laboratories per ASHREA 62.1 increase with LVDL or by the effectiveness. While safety is the primary concern, different air change rates (ACH) rates present an opportunity to save on operational costs through reduced treatment to supply air and also exhaust fan energy saving through staging fan operation.
Reference the Greenheck Fresh Air blog post on laboratory exhaust redundancy for descriptions of the different types.
Airstream Protection
Personnel protection is at the center of the LDVL discussion. The airborne discharge of chemicals or hazardous materials from the laboratory poses a risk for individuals on the rooftop. An aspect sometimes overlooked is the handling of exposed airstream components when performing maintenance or repairs. A fan system with a sealed airstream provides a protective cover and gasketing for drive components, such as the motor, shaft, bearings, and sheaves to protect against contaminants, but still within the airstream. This design is acceptable when the degree of hazard severity is between negligible to moderate depending on the chemical. Service may require coming in contact with parts sealing the drive components. The alternative to a sealed airstream is an isolated one. Drive components are completely outside of the contaminated airstream. Two housing designs that feature an isolated airstream are the scrolled centrifugal and bifurcated housing designs, allowing for safer inspection or service by maintenance personnel.
Appropriate personal protective equipment should be worn when servicing a laboratory exhaust system.
Exhaust Fan Discharge
Exhaust discharge becomes more critical as the design level increases. Three different discharge types are available that address design level requirements, add to the height of the system and produce a high-velocity discharge that helps in the dispersion of the contaminated plume.
A high plume nozzle is an engineered cone producing higher discharge velocities and increasing the exhaust effluent plume height Effective plume height, which includes the fan system height and exhaust effluent plume height, is important in preventing contaminated exhaust effluent from being re-entrained into the laboratory or adjacent buildings through make-up air systems or windows.
A high plume dilution wind band combined with a high-velocity nozzle entrains outside air, diluting the exhaust effluent and directs exhaust airstream up away from the building. Dilution provides for lower contaminant concentration levels downwind of the exhaust system.
A variable geometry nozzle maintains a high-discharge velocity in a variable volume laboratory application without passing air through the bypass air damper. Energy costs are reduced by slowing the fan speed and not bypassing outside air while still having a high discharge plume height.
Bypass Air Plenum and Damper
Dilution is a control strategy for all five LVDL categories. It limits exposure risk inside the laboratory and also reduces the contamination risk from the discharge exhaust effluent. Dilution comes with the price of high ventilation rates, and combined with laboratories often requiring 100% outside air, it is a large operating expense. This expense is where an exhaust system with a plenum and bypass air damper can help.
As a system control strategy to reduce the operating costs associated with dilution rates and high-level LVDL categories, many laboratories utilize a variable volume exhaust system. Variable air volume (VAV) laboratory systems save operation costs by reducing the amount of conditioned air exhausted during periods when high ventilation rates are not required. The building’s laboratory exhaust requirements such as effective plume height and dilution levels are maintained during these periods utilizing unconditioned air, from outside the building, to make up the difference with a bypass damper and plenum. An exhaust system’s bypass damper(s) percent open position is modulated to balance laboratory airflow rates and also satisfy a constant airflow through the exhaust fan. The VAV control strategy, including a plenum and bypass air damper, reduces operating expenses and maintains laboratory safety both inside and out.
System Height
System height, including stack height, is mentioned as a component of modern laboratory control systems in the ASHRAE guide. It is a safety consideration in laboratory exhaust systems for all LVDL classifications to protect maintenance personnel. Both NFPA 45 and the ANSI/AIHA Z9.5 - Laboratory Design Guide, recommend a minimum of a ten-foot-high system discharge height protecting individuals on the roof deck from inhaling or contacting contaminated exhaust effluent or particulates.
Drive Type
Fans used in laboratory exhaust utilize one of two drive system types; belt or direct drive. All the LVDL categories discuss redundancy and control strategies to lower operating costs in laboratories. Lower operating costs also relates to the choice of drive type utilized in the exhaust system.
Belt drive systems have a motor, fan drive shaft, high-performance bearings, and a set of belts and sheaves. Recommendations call for belt drive exhaust system to utilize a minimum of two belts with a 2.0 drive service factor. This two-belt minimum provides for system redundancy and reliability. Should a belt break, the remaining belts can handle 100% of the load without losing containment in the fume hood.
Direct drive systems have fewer components for potential failure and require less maintenance. Fans with a direct drive system are more efficient, eliminating losses through the fan belts, pulleys and fan shaft bearings. If paired with a variable frequency drive (VFD) provides for potential operational cost savings when adjusting the fan speed to match varying flows from the laboratory.
Additional Considerations
Link to E3 Green Technology
Other features also play a role in determining the best laboratory exhaust system with corresponding laboratory LDVL and overall laboratory risk assessment. These include footprint, overall height, sound, and weight.
Learn more about laboratory exhaust systems here or redundant lab exhaust systems. You can also learn more about LDVL by downloading the Classification of Laboratory Design Levels. It is free to download on the ASHRAE website or from TechStreet.
Laboratory ExhaustLaboratory Ventilation Basics
Laboratory Ventilation Basics
Laboratories can be dangerous places.
Because laboratories handle toxic chemicals, combustible substances, flammable solvents, harmful organisms, obnoxious vapours and so on…
Various control measures are necessary to make laboratories safe and comfortable places to work.
Most people are aware that only highly trained and authorised personnel are allowed to work in laboratories, and they use PPE (Personal Protection Equipment such as lab coats, safety goggles, respiratory masks etc). However, some may not know that a lot of effort goes in to incorporating appropriate engineering controls while designing and fitting out new laboratories. This provides safety at three levels – laboratory users, wider organisation and the surrounding neighbourhood.
For lab designers, understanding of the type of research/activities carried out and regulatory compliance sought by clients is an important step to determine the type and level of ventilation needed for their new facility.
Ventilation is important from a safety as well as financial point of view as it demands major capital and operating costs. Laboratories are energy intensive environments, consuming 4–6 six times more energy per square metre than standard office or commercial buildings and more than 60% of a laboratory’s energy consumption can be attributed to the HVAC system (Manufacturing Chemist).
Laboratory ventilation is a complex topic needing specialist input. However, in this article we present an overview and some basics.
HVAC & Lab Ventilation:
A more commonly used term HVAC - Heating, Ventilation, and Air Conditioning - is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and an acceptable indoor air quality. Laboratory ventilation, a part of the HVAC system, is the supply of a fresh/clean air to displace contaminated air and dilute it to safe levels. It consists of two vital factors - air handling and filtration systems.
A basic HVAC unit can be as shown below,
PC: Lightfoot Mechanical
Air is continuously exchanged between buildings and their surroundings. The rate at which air is exchanged is an important property for the purposes of ventilation design and heat loss calculations and is expressed in ‘air changes per hour’ (ach).
Air changes per hour, or air change rate, abbreviated ACH OR ACPH, is a measure of the air volume added to or removed from a space (normally a room or house) divided by the volume of the space. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced.
Different laboratory areas and rooms in the building will need a different number of air changes. Rooms containing fume cupboards and higher containment need a greater number of air changes than a general laboratory.
The type of material handled in the space will determine if the exhaust needs treating (e.g. HEPA (High Efficiency Particulate Absorption) filters, scrubbers) before discharging into the atmosphere or re-circulating back. For example, biology laboratories, BSL (Biosafety Level) 1 to 4, will involve increasing hazard level and filtration needs. BSL1 being the simplest and BSL4 the most complex.
Pharmaceutical clean room environments need a very high number of air changes as well as HEPA filtration for supply and exhaust air. Check our guidance on clean rooms here.
Guidance on ACH:
In the UK, there are no prescriptive values for air change rates. The rate determined depends on the type of room and the activity being undertaken. Typical industrial applications range between 5 and 15 air changes per hour (CIBSE).
A word of caution about the ACH rate - Ventilation is a tool for controlling exposure. Since a ventilation system designer cannot know all possible laboratory operations, chemicals to be used, and their potential for release of fumes and other toxic agents, single air exchange rate cannot be specified that will meet all conditions.
Furthermore, air changes per hour is not the appropriate concept for designing contaminant control systems. Excessive airflow with no demonstrable safety benefit other than meeting an arbitrary air change rate can waste considerable energy.
An early and accurate assessment of clients’ needs, and risk levels through a collaborative approach between lab users, designers, health & safety representatives and M&E engineers/consultants to propose an appropriate ventilation strategy is recommended.
Some or all the criteria below can be used in determining what that looks like:
- Facility Layout and workflow
- Temperature, relative humidity
- Air pressure differentials between rooms
- Number of air-changes for each room
- Air velocity and airflow pattern
- Number of particles in the air
- Filters (type, position)
Future Trends:
To minimise the energy consumption and environmental impact of ventilation equipment, numerous initiatives have been put in place by the industry to make future labs smarter. New ways make ventilation central to the design process involving M&E and key stakeholders early in the process, considers it as a dynamic than static process making monitoring and quality control central and the design process focuses on space as activity based zoning and risk assessment for improved efficiency and better control.
Building Choice:
While choosing a new building for laboratory use, it is important to assess the size of the plant room needed and whether enough space is available for distribution of services. Thought needs to be given to structural slab to slab height and to creating sufficient space for a network of supply and exhaust ducts in the chosen building.
Recently, we worked on a project located on an upper floor of a busy city centre building. Initially, the client had requested high ACH rates throughout the lab (BSL2) area. But constraints with the external and roof top plant space, the lack of ceiling space for extensive ducting and the landlord’s reluctance to grant permission allowed us to re-visit their ventilation needs. After individual room analysis and risk assessment a new flexible ventilation strategy was proposed requiring a lesser plant area and improved future energy consumption.
For more Laboratory Ventilation In HVACinformation, please contact us. We will provide professional answers.